Contrast-enhanced ultrasound (CEUS) has excellent diagnostic accuracy in differentiating focal liver lesions: results from a Swiss tertiary gastroenterological centre

  • Mikael Sawatzki
  • Christa Meyenberger
  • Stephan Brand
  • David Semela
DOI
https://doi.org/10.4414/smw.2019.20087
Cite this as:
Swiss Med Wkly. 2019;149:w20087
Published
30.06.2019

Summary

INTRODUCTION

Focal liver lesions (FLLs) are common on conventional ultrasound. Contrast-enhanced ultrasound (CEUS) is highly accurate for differentiating between benign and malignant FLLs, with an accuracy comparable to that of contrast-enhanced CT and contrast-enhanced MRI. Notably, there is no evidence supporting the routine use of CEUS for evaluating benign and malignant FLLs in Switzerland. In this study, we assessed the use of CEUS in a clinical routine setting in a tertiary Swiss gastroenterology centre.

METHODS

We analysed all CEUS investigations performed on new or unclear FLLs in our department between November 2011 and March 2013. In all patients, the CEUS results (benign versus malignant FLLs) were compared with CT or MRI findings. To avoid interobserver variation, CEUS was performed by a single experienced gastroenterologist using one ultrasound device (Acuson Sequoia 512®, Siemens, Erlangen, Germany). All patients were examined using the intravenous application of 1.5–2 ml Sonovue®. An FLL with arterial enhancement with wash-out in any vascular phase was defined as a malignant FLL. Malignant FLLs were confirmed by histology.

RESULTS

The study included 112 patients. None of them experienced side effects after injection of Sonovue®. The final diagnoses included malignant FLLs (n = 37) and benign FLLs (n = 75) that ranged in size from 7 to 120 mm. The biopsy-proven malignant FLLs (n = 37) included hepatocellular carcinoma, metastatic cancers, peripheral cholangiocarcinoma and primary B-cell lymphoma. CEUS correctly identified 36 out of 37 malignant FLLs, showing a sensitivity of 96–97.2% and a negative predictive value (NPV) of 94.1–98.5%. In contrast, CT/MRI did not identify three metastatic cancers, one HCC, one peripheral cholangiocarcinoma and one primary B-cell lymphoma in the liver as malignant FLLs, resulting in a sensitivity of 80.6–80.9% and an NPV of 78.9–89.8%. All these malignant FLLs were correctly classified by CEUS.

CONCLUSIONS

In daily clinical practice, CEUS is a fast imaging tool which uses a renal-independent contrast agent and shows excellent accuracy for differentiating between malignant and benign FLLs in about five minutes. The use of CEUS helps to avoid false negative results from CT/MRI and improves sensitivity. CEUS should be the first diagnostic step for investigating new or unclear FLLs.

References

  1. Horta G, López M, Dotte A, Cordero J, Chesta C, Castro A, et al. Lesiones focales hepáticas benignas: un hallazgo frecuente a la tomografía computada [Benign focal liver lesions detected by computed tomography: Review of 1,184 examinations]. Rev Med Chil. 2015;143(2):197–202. Article in Spanish. doi:.https://doi.org/10.4067/S0034-98872015000200007
  2. Bahirwani R, Reddy KR. Review article: the evaluation of solitary liver masses. Aliment Pharmacol Ther. 2008;28(8):953–65. doi:.https://doi.org/10.1111/j.1365-2036.2008.03805.x
  3. Friedrich-Rust M, Klopffleisch T, Nierhoff J, Herrmann E, Vermehren J, Schneider MD, et al. Contrast-enhanced ultrasound for the differentiation of benign and malignant focal liver lesions: a meta-analysis. Liver Int. 2013;33(5):739–55. doi:.https://doi.org/10.1111/liv.12115
  4. Seitz K, Strobel D, Bernatik T, Blank W, Friedrich-Rust M, Herbay A, et al. Contrast-Enhanced Ultrasound (CEUS) for the characterization of focal liver lesions - prospective comparison in clinical practice: CEUS vs. CT (DEGUM multicenter trial). Ultraschall Med. 2009;30(4):383–9. doi:.https://doi.org/10.1055/s-0028-1109673
  5. Seitz K, Bernatik T, Strobel D, Blank W, Friedrich-Rust M, Strunk H, et al. Contrast-enhanced ultrasound (CEUS) for the characterization of focal liver lesions in clinical practice (DEGUM Multicenter Trial): CEUS vs. MRI--a prospective comparison in 269 patients. Ultraschall Med. 2010;31(5):492–9. doi:.https://doi.org/10.1055/s-0029-1245591
  6. Strobel D, Bernatik T, Blank W, Schuler A, Greis C, Dietrich CF, et al. Diagnostic accuracy of CEUS in the differential diagnosis of small (≤ 20 mm) and subcentimetric (≤ 10 mm) focal liver lesions in comparison with histology. Results of the DEGUM multicenter trial. Ultraschall Med. 2011;32(6):593–7. doi:.https://doi.org/10.1055/s-0031-1271114
  7. Piscaglia F, Bolondi L ; Italian Society for Ultrasound in Medicine and Biology (SIUMB) Study Group on Ultrasound Contrast Agents. The safety of Sonovue in abdominal applications: retrospective analysis of 23188 investigations. Ultrasound Med Biol. 2006;32(9):1369–75. doi:.https://doi.org/10.1016/j.ultrasmedbio.2006.05.031
  8. Claudon M, Dietrich CF, Choi BI, Cosgrove DO, Kudo M, Nolsøe CP, et al. Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver--update 2012: a WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS. Ultraschall Med. 2013;34(1):11–29.
  9. Minimum training requirements for the practice of Medical Ultrasound in Europe. Ultraschall Med. 2010;31(4):426–7. doi:.https://doi.org/10.1055/s-0030-1263214
  10. Burrowes DP, Medellin A, Harris AC, Milot L, Wilson SR. Contrast-enhanced US approach to the diagnosis of focal liver masses. Radiographics. 2017;37(5):1388–400. doi:.https://doi.org/10.1148/rg.2017170034
  11. Wilson SR, Kim TK, Jang HJ, Burns PN. Enhancement patterns of focal liver masses: discordance between contrast-enhanced sonography and contrast-enhanced CT and MRI. AJR Am J Roentgenol. 2007;189(1):W7–12. doi:.https://doi.org/10.2214/AJR.06.1060
  12. Dietrich F, Averkiou M, Bachmann Nielsen M, Barr RG, Burns PN, Calliada F, et al. How to perform Contrast-Enhanced Ultrasound (CEUS). Ultrasound Int Open. 2018;4(1):E2–15.
  13. Maximova N, Gregori M, Zennaro F, Sonzogni A, Simeone R, Zanon D. Hepatic Gadolinium Deposition and Reversibility after Contrast Agent-enhanced MR Imaging of Pediatric Hematopoietic Stem Cell Transplant Recipients. Radiology. 2016;281(2):418–26. doi:.https://doi.org/10.1148/radiol.2016152846
  14. Hu HH, Pokorney A, Towbin RB, Miller JH. Increased signal intensities in the dentate nucleus and globus pallidus on unenhanced T1-weighted images: evidence in children undergoing multiple gadolinium MRI exams. Pediatr Radiol. 2016;46(11):1590–8. doi:.https://doi.org/10.1007/s00247-016-3646-3
  15. Murata N, Gonzalez-Cuyar LF, Murata K, Fligner C, Dills R, Hippe D, et al. Macrocyclic and Other Non-Group 1 Gadolinium Contrast Agents Deposit Low Levels of Gadolinium in Brain and Bone Tissue: Preliminary Results From 9 Patients With Normal Renal Function. Invest Radiol. 2016;51(7):447–53. doi:.https://doi.org/10.1097/RLI.0000000000000252
  16. Giesel FL, Delorme S, Sibbel R, Kauczor HU, Krix M. Kontrastverstärkter Ultraschall zur Charakterisierung von inzidentellen Leberläsionen - eine ökonomische Betrachtung im Vergleich zur Mehrphasen-Computertomografie [Contrast-enhanced ultrasound for the characterization of incidental liver lesions - an economical evaluation in comparison with multi-phase computed tomography]. Ultraschall Med. 2009;30(3):259–68. Article in German.
  17. Westwood M, Joore M, Grutters J, Redekop K, Armstrong N, Lee K, et al. Contrast-enhanced ultrasound using SonoVue® (sulphur hexafluoride microbubbles) compared with contrast-enhanced computed tomography and contrast-enhanced magnetic resonance imaging for the characterisation of focal liver lesions and detection of liver metastases: a systematic review and cost-effectiveness analysis. Health Technol Assess. 2013;17(16):1–243. doi:.https://doi.org/10.3310/hta17090
  18. Colombo M, Forner A, Ijzermans J, Paradis V, Reeves H, Vilgrain V, et al.; European Association for the Study of the Liver (EASL). EASL Clinical Practice Guidelines on the management of benign liver tumours. J Hepatol. 2016;65(2):386–98.
  19. Galle PR, Forner A, Llovet JM, Mazzaferro V, Piscaglia F, Raoul JL, et al.; European Association for the Study of the Liver. Electronic address: easloffice@easloffice.eu; European Association for the Study of the Liver. EASL Clinical Practice Guidelines: Management of hepatocellular carcinoma. J Hepatol. 2018;69(1):182–236.

Most read articles by the same author(s)

<< < 1 2