BACKGROUND
Biosynthetic mesh may represent an improvement on biological and large pore synthetic meshes for high-risk complex ventral hernia repair. This study aimed to evaluate the performance of polyglycolic acid (PGA):trimethylene carbonate (TMC) biosynthetic mesh for reinforcement of the midline fascial closure in a single-stage repair of complex ventral hernias in high-risk patients.
METHODS
A retrospective review was undertaken for patients who underwent a planned open single-stage complex ventral hernia repair with a single unit of PGA:TMC biosynthetic mesh between May 2013 and August 2017. Data on outcome variables were recorded and quality of life assessed using the Short Form-12 (SF-12) instrument.
RESULTS
Overall, 56 patients underwent abdominal wall reconstruction for complex ventral hernias. All meshes were placed in the retrorectus position. Some 39% underwent component separation. The majority of patients (86%, n = 48) had high risk (grade 2 or 3) hernias according to the Ventral Hernia Working Group classification. Overall hernia recurrence rate was 3.6% (n = 2). Postoperative surgical site infection occurred in 26.8% (n = 15). Median follow-up by clinical examination was 6 months (range 4–17). Median telephone follow-up was 21 months (range 4–54). Pre- and post-treatment SF-12 quality of life assessments demonstrated significant improvements in both the physical and mental components.
CONCLUSION
This study reports a large series of abdominal wall reconstructions using biosynthetic mesh in complex ventral hernia. The findings indicate promising early outcome data associated with use of biosynthetic mesh. Larger well-controlled studies with longer follow-up are needed for confirmation of these findings.
References
- Atema JJ, de Vries FE, Boermeester MA. Systematic review and meta-analysis of the repair of potentially contaminated and contaminated abdominal wall defects. Am J Surg. 2016;212(5):982–995.e1. doi:.https://doi.org/10.1016/j.amjsurg.2016.05.003
- Atema JJ, Furnée EJ, Maeda Y, Warusavitarne J, Tanis PJ, Bemelman WA, et al. Major Complex Abdominal Wall Repair in Contaminated Fields with Use of a Non-cross-linked Biologic Mesh: A Dual-Institutional Experience. World J Surg. 2017;41(8):1993–9. doi:.https://doi.org/10.1007/s00268-017-3962-2
- Cross W, Kumar A, Chandru Kowdley G. Biological mesh in contaminated fields--overuse without data: a systematic review of their use in abdominal wall reconstruction. Am Surg. 2014;80(1):3–8. doi:.https://doi.org/10.1177/000313481408000104
- Rosen MJ. Biologic mesh for abdominal wall reconstruction: a critical appraisal. Am Surg. 2010;76(1):1–6. doi:.https://doi.org/10.1177/000313481007600101
- Kim H, Bruen K, Vargo D. Acellular dermal matrix in the management of high-risk abdominal wall defects. Am J Surg. 2006;192(6):705–9. doi:.https://doi.org/10.1016/j.amjsurg.2006.09.003
- Kim M, Oommen B, Ross SW, Lincourt AE, Matthews BD, Heniford BT, et al. The current status of biosynthetic mesh for ventral hernia repair. Surg Technol Int. 2014;25:114–21.
- Liang MK, Holihan JL, Itani K, Alawadi ZM, Gonzalez JR, Askenasy EP, et al. Ventral Hernia Management: Expert Consensus Guided by Systematic Review. Ann Surg. 2017;265(1):80–9. doi:.https://doi.org/10.1097/SLA.0000000000001701
- Slater NJ, Montgomery A, Berrevoet F, Carbonell AM, Chang A, Franklin M, et al. Criteria for definition of a complex abdominal wall hernia. Hernia. 2014;18(1):7–17. doi:.https://doi.org/10.1007/s10029-013-1168-6
- Muysoms FE, Miserez M, Berrevoet F, Campanelli G, Champault GG, Chelala E, et al. Classification of primary and incisional abdominal wall hernias. Hernia. 2009;13(4):407–14. doi:.https://doi.org/10.1007/s10029-009-0518-x
- Stoppa RE. The treatment of complicated groin and incisional hernias. World J Surg. 1989;13(5):545–54. doi:.https://doi.org/10.1007/BF01658869
- Mangram AJ, Horan TC, Pearson ML, Silver LC, Jarvis WR ; Hospital Infection Control Practices Advisory Committee. Guideline for prevention of surgical site infection, 1999. Infect Control Hosp Epidemiol. 1999;20(4):247–78, quiz 279–80. doi:.https://doi.org/10.1086/501620
- Breuing K, Butler CE, Ferzoco S, Franz M, Hultman CS, Kilbridge JF, et al.; Ventral Hernia Working Group. Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair. Surgery. 2010;148(3):544–58. doi:.https://doi.org/10.1016/j.surg.2010.01.008
- Kanters AE, Krpata DM, Blatnik JA, Novitsky YM, Rosen MJ. Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs. J Am Coll Surg. 2012;215(6):787–93. doi:.https://doi.org/10.1016/j.jamcollsurg.2012.08.012
- Kissane NA, Itani KMF. A decade of ventral incisional hernia repairs with biologic acellular dermal matrix: what have we learned? Plast Reconstr Surg. 2012;130(5, Suppl 2):194S–202S. doi:.https://doi.org/10.1097/PRS.0b013e318265a5ec
- Patel KM, Bhanot P. Complications of acellular dermal matrices in abdominal wall reconstruction. Plast Reconstr Surg. 2012;130(5, Suppl 2):216S–24S. doi:.https://doi.org/10.1097/PRS.0b013e318262e186
- Köckerling F, Alam NN, Antoniou SA, Daniels IR, Famiglietti F, Fortelny RH, et al. What is the evidence for the use of biologic or biosynthetic meshes in abdominal wall reconstruction? Hernia. 2018;22(2):249–69. doi:.https://doi.org/10.1007/s10029-018-1735-y
- Stephan B, Ramshaw B, Forman B. Value-based Clinical Quality Improvement (CQI) for Patients Undergoing Abdominal Wall Reconstruction. Surg Technol Int. 2015;26:135–42.
- Jacobson GR, Chao JJ. Clinical use of Gore® Bio-a® tissue reinforcement in ventral hernia repair using the components separation technique. 2010. http://www.goremedical.com/resources/dam/assets/AP2975-ENI.pdf Accessed 2017 August 13.
- Plymale MA, Davenport DL, Dugan A, Zachem A, Roth JS. Ventral hernia repair with poly-4-hydroxybutyrate mesh. Surg Endosc. 2018;32(4):1689–94. doi:.https://doi.org/10.1007/s00464-017-5848-7
- Rosen MJ, Bauer JJ, Harmaty M, Carbonell AM, Cobb WS, Matthews B, et al. Multicenter, Prospective, Longitudinal Study of the Recurrence, Surgical Site Infection, and Quality of Life After Contaminated Ventral Hernia Repair Using Biosynthetic Absorbable Mesh: The COBRA Study. Ann Surg. 2017;265(1):205–11. doi:.https://doi.org/10.1097/SLA.0000000000001601
- García-Ureña MÁ, López-Monclús J, Cuccurullo D, Blázquez Hernando LA, García-Pastor P, Reggio S, et al. Abdominal Wall Reconstruction Utilizing the Combination of Absorbable and Permanent Mesh in a Retromuscular Position: A Multicenter Prospective Study. World J Surg. 2019;43(1):149–58. doi:.https://doi.org/10.1007/s00268-018-4765-9
- White TJ, Santos MC, Thompson JS. Factors affecting wound complications in repair of ventral hernias. Am Surg. 1998;64(3):276–80.
- Xourafas D, Lipsitz SR, Negro P, Ashley SW, Tavakkolizadeh A. Impact of mesh use on morbidity following ventral hernia repair with a simultaneous bowel resection. Arch Surg. 2010;145(8):739–44. doi:.https://doi.org/10.1001/archsurg.2010.144
- Nasajpour H, LeBlanc KA, Steele MH. Complex hernia repair using component separation technique paired with intraperitoneal acellular porcine dermis and synthetic mesh overlay. Ann Plast Surg. 2011;66(3):280–4. doi:.https://doi.org/10.1097/SAP.0b013e3181e9449d
- Clemens MW, Selber JC, Liu J, Adelman DM, Baumann DP, Garvey PB, et al. Bovine versus porcine acellular dermal matrix for complex abdominal wall reconstruction. Plast Reconstr Surg. 2013;131(1):71–9. doi:.https://doi.org/10.1097/PRS.0b013e3182729e58
- Blair LJ, Cox TC, Huntington CR, Groene SA, Prasad T, Lincourt AE, et al. The effect of component separation technique on quality of life (QOL) and surgical outcomes in complex open ventral hernia repair (OVHR). Surg Endosc. 2017;31(9):3539–46. doi:.https://doi.org/10.1007/s00464-016-5382-z
- Madani A, Niculiseanu P, Marini W, Kaneva PA, Mappin-Kasirer B, Vassiliou MC, et al. Biologic mesh for repair of ventral hernias in contaminated fields: long-term clinical and patient-reported outcomes. Surg Endosc. 2017;31(2):861–71. doi:.https://doi.org/10.1007/s00464-016-5044-1